Explore UL AWM specifications 3132, 3135, 3512, 3122, 3239 and 4476. These guides compare construction, ratings and intended use; they are not a catalogue of certified ANYANG products. Find the style on your drawing, compare the construction, then choose a product and wire size.

UL AWM specifications describe construction and use. Product certification is tied to the manufacturer and constructions covered by its UL record.

Cross-sections show construction, not actual size. Enlarge an image to see the layers, or select a UL style to explore specifications.

6 UL style guides

AWM STYLESINGLE CONDUCTOR

Silicone-insulated single core

UL 3132

Single-core silicone wire

STYLE REFERENCE150°C (302°F) · 300 V AC

View construction and rating guide

AWM STYLESINGLE CONDUCTOR

Silicone-insulated single core

UL 3135

Single-core silicone wire

STYLE REFERENCE200°C (392°F) · 600 V AC

View construction and rating guide

AWM STYLESINGLE CONDUCTOR

Silicone-insulated single core

UL 3512

Single-core silicone wire

STYLE REFERENCE200°C (392°F) · 600 V AC

View construction and rating guide

AWM STYLESINGLE CONDUCTOR

Nonmetallic outer braid

UL 3122

Braided single-core wire

STYLE REFERENCE200°C (392°F) · 300 V AC

View construction and rating guide

AWM STYLESINGLE CONDUCTOR

Voltage-specific insulation

UL 3239

High-voltage single-core wire

STYLE REFERENCEDC voltage · version-specific

View construction and rating guide

AWM STYLEMULTICORE

Insulated cores + outer jacket

UL 4476

Silicone-jacketed multicore cable

STYLE REFERENCE2+ cores · version-specific ratings

View construction and rating guide

KNOW WHAT YOU ARE COMPARING

UL AWM specification, product and wire size

UL style
Describes a construction and its permitted conditions of use. Different styles can share a headline rating.
Product specification
Defines the actual conductor, insulation, dimensions and ratings of the cable being supplied.
Wire size
AWG or mm² identifies conductor size. Confirm stranding, finished diameter and termination separately.

FROM A STYLE TO A SPECIFICATION

Not sure which style to use?

Send the drawing or equipment specification. Include voltage, temperature and whether the connection is inside or outside the equipment.

Cable cross-section

Cross-section schematic · not to scale. Strand count, colours and proportions are illustrative.