ANYANG · Quality Silicone Cable Manufacturer
DownloadsContactEnglish
Request a Quote ↗

UL AWM specification guide

UL 3239 Silicone Wire Specification

High-voltage DC
wire specifications.

UL 3239 covers high-voltage DC wire. For a silicone-insulated version, the specification includes conductor size, voltage, temperature and insulation dimensions.

Voltage basis
High-voltage DC
Material to specify
Silicone version
Wire specification
The complete wire version
Why specify this style? ↓
SILICONE-INSULATED VERSIONUL 3239
  • Conductor
  • Silicone insulation
Representative silicone version, not to scale. The drawing does not indicate a voltage rating or a required insulation thickness.

THE ROLE OF THIS STYLE

Why specify UL 3239 high-voltage silicone wire?

A high-voltage DC connection needs a wire selected for that electrical duty. A familiar single-core shape or a high temperature rating does not tell you its working voltage.

UL 3239 covers multiple voltage and insulation constructions. Ratings and dimensions depend on the version.

START WITH THE REQUIREMENTTHEN IDENTIFY THE VERSION

Electrical duty

The maximum working voltage and its waveform.

State DC operation and any AC, pulse or transient conditions separately.

Material & temperature

The required silicone construction and temperature rating.

A material’s thermal capability and the product’s recognised temperature can be different.

Physical construction

The conductor, insulation and finished diameter.

Use the dimensional specification belonging to that same voltage version.

Do not combine the highest voltage from one version with the temperature or dimensions of another.

THREE DIFFERENT QUESTIONS

Working voltage is not
test voltage.

Give each electrical condition its own name in the enquiry. A single value labelled “voltage” leaves too much unspecified.

Working DC voltage
The voltage the connection must withstand in its intended operating conditions.

Specify the maximum operating requirement, the connection arrangement and the equipment requirement. Select a product rated for that duty.

Test voltage
A verification condition used with a defined method, duration and acceptance criterion.

A short-duration test result is not permission to operate continuously at that voltage. Request the test basis as well as the value.

AC, pulses & transients
Additional electrical conditions that need their own assessment.

Do not use a DC marking as an automatic AC or pulse rating. Describe the waveform and relevant peaks for engineering review.

ONE NUMBER, MORE THAN ONE CONSTRUCTION

Silicone versions of UL 3239

UL 3239 is not a silicone-only designation. The illustrated wire is one material and construction choice within a broader style.

Conductor

Carries the electrical connection. Conductor size, finish and stranding affect the connection and assembly.

Conductor specification

Cross-section or AWG, material, stranding, current requirement and terminal compatibility.

Silicone insulation

The insulating material in this example. Other UL 3239 products can use different materials.

Insulation specification

The exact compound, recognised temperature, insulation dimensions and voltage version.

Additional layers, if required

A screen, covering or jacket may be part of a different construction. None is shown in the representative section.

Additional layer requirements

Whether extra layers are required, their function, dimensions and the complete product recognition.

Keep the product specification together: material + conductor + voltage + temperature + insulation dimensions + finished diameter. Confirm changes as a new or revised version rather than assuming the other ratings remain unchanged.

Technical references: Alpha Wire 392040 and Rowe UL 3239. These manufacturers' examples do not establish ANYANG product recognition.

SIMILAR SILHOUETTE, DIFFERENT SELECTION

Temperature and voltage rating

The same-looking single conductor can belong to a very different electrical specification.

Selection distinctions, not permission to substitute one style for another. On a small screen, swipe across the table.

Voltage basis, material and dimensional differences
What matters?UL 3239THIS STYLEUL 3135 ↗UL 3512 ↗
Electrical referenceHigh-voltage DC; select a defined rated version600 V AC historical reference600 V AC historical reference
Material identitySpecify silicone; the style also covers other materialsExtruded silicone rubberExtruded silicone rubber
TemperatureConfirm the recognised temperature of that voltage version200°C (392°F) historical reference200°C (392°F) historical reference
Dimensional selectionConductor and insulation tied to the specified voltage constructionDefined conductor range and wall requirementsWall requirements depend on the conductor-size band

Sources: UL 3239 historical style reference, UL 3135 historical style reference, UL 3512 historical style reference. Historical style ranges are not a statement of current supply.

REVIEW THE COMPLETE HIGH-VOLTAGE CONNECTION

The complete high-voltage connection

Have the equipment designer review the complete connection. The complete connection must meet the equipment's requirements for terminations, insulation interfaces and electrical clearances.

DESCRIBE THE INSTALLATION

Operating conditions

  • Maximum working voltage, waveform and relevant peaks.
  • Conductor current, temperature and routing conditions.
  • Termination design, exposed ends and insulation interfaces.
  • Humidity, contamination, movement and required verification.

DO NOT INFER FROM THE STYLE NUMBER

Termination suitability
The terminal and connection method need their own compatibility review.
Electrical clearances
Determine them from the equipment requirements and actual installation, not the cross-section picture.
Use approval
An AWM style does not approve the wire for every high-voltage device or installation.

BEFORE YOU SPECIFY

Frequently asked questions

Does every UL 3239 wire have the same voltage rating?

No. Different constructions can have different ratings. Ask for a specification that binds the voltage to the actual material, conductor, dimensions and recognised temperature.

Can I use a DC-rated version for AC operation?

Not automatically. Describe the AC or pulse conditions so the wire version and the complete connection can be assessed.

Does a thicker-looking insulation mean a higher rating?

Not by appearance alone. Material, construction and product recognition matter. The illustration explains the layers; it is not a voltage-selection chart.

Why can a catalogue show two temperature figures?

A supplier may distinguish a material or operating temperature range from a recognised temperature rating. Read the labels and confirm the rating applicable to the specific ordered version.

FROM STYLE TO PRODUCT SPECIFICATION

Discuss a UL 3239 specification

For a quotation, include the required operating voltage, wire size, dimensional limits and quantity.

Electrical requirement

Working DC voltage, AC or pulse conditions, current and required test basis.

Wire & installation

Conductor size, silicone requirement, dimensional limits and connection environment.

Product evidence

Required markings, recognition and drawings for the exact proposed version.

Request a quotation

We offer free samples.

UL 3239 cross-section

Representative silicone version, not to scale. The drawing does not indicate a voltage rating or a required insulation thickness.

Document

Open full image ↗Download ↓