INTERNAL CONNECTIONS
Luminaire internal leads
Provide the connection diagram, conductor size, colour and insulation diameter for the luminaire assembly.
APPLICATION / Lighting equipment
Internal wiring for lighting fixtures.
AGR is a silicone-insulated single-core wire with fine-stranded tinned copper and no outer sheath. Listed sizes are 0.3–16 mm²; the fixed-installation rating is −60 °C (−76°F) to +180 °C (356°F) continuous and +200 °C (392°F) short-term.

AT A GLANCE
Each lighting connection and the silicone wire we start from.
| Connection | Cable construction | Key point |
|---|---|---|
| Luminaire internal leads | AGR silicone single-core wire, 0.3 mm² to 16 mm² | No outer sheath; ventilate the fixture above +100 °C (212°F) |
| Driver-to-light connection | AGR wire, or silicone-sheathed cable if a common sheath is required | Single wires or one sheathed cable, as your drawing shows |
| Ignition or special-voltage circuits | Separate special-duty specification | Standard AGR is not rated for ignition circuits |
CONNECTION TASKS
Inside the fixture, AGR runs as a single insulated lead. Outdoor luminaires and ignition circuits need their own rating.

INTERNAL CONNECTIONS
Provide the connection diagram, conductor size, colour and insulation diameter for the luminaire assembly.

CIRCUIT REVIEW
State the electrical duty and distance between connection points. Identify whether individual wires or a sheathed cable are specified.
SEPARATE SPECIFICATION
The AGR datasheet gives 300/300 V below 0.5 mm² and 300/500 V from 0.5 mm². It does not specify ignition-pulse performance.
SELECTION CHECKS
Include these conditions with your enquiry so we can select the right cable.
Temperature along the wire route, ventilation and the space inside the fixture set the wire's thermal duty.
The connection function, working voltage and current, and any ignition requirement decide the wire rating.
Wire size, colour, length, terminals and the documents the luminaire needs complete the specification.
OUR CABLE
Construction and technical data.

AGR / SINGLE-CORE WIRE
APPLICATION LIMITS
A lighting application can involve more than one wire or cable specification.
TECHNICAL DOCUMENTS
Product datasheet and quotation checklist.
Construction, applications and size table.
Certification is model-specific; the marks on a datasheet do not replace a certificate.Send a drawing or existing cable specification with the following information.
BEFORE YOU SPECIFY
No. AGR is a single insulated conductor without an outer sheath.
The AGR datasheet does not list outdoor-luminaire approval or an ignition-pulse rating.
AGR is listed from 0.3 mm² to 16 mm², with outside diameters from 1.8 mm to 8.0 mm. Sizes from 0.5 mm² are rated U0/U 300/500 V; smaller sizes 300/300 V.
CUSTOM SUPPORT & ENQUIRY
Need a custom size or construction? Send your drawing, operating conditions and required quantity for a quotation.