Unscreened
Silicone Hook-Up & Lead Wire
- Core sizes
- 2 AWG / 4 AWG / 6 AWG / 8 AWG / 10 AWG / 12 AWG / 14 AWG / 16 AWG / 18 AWG / 20 AWG / 22 AWG / 24 AWG / 26 AWG / 28 AWG
Silicone wire & cable / Extra-Flexible Silicone Wires & Cables
Fine-strand silicone designs for compact routing and defined motion.
Compare conductor size, strand count and individual wire diameter. The factory 18 AWG single-core example uses 150/0.08 mm stranding and a 2.3 mm outside diameter; finer-strand and moving-cable designs can be developed to a separate project specification.

Sheathed multicore reference illustration. Confirm the strand build, core arrangement and layers in the selected product drawing.
Browse the range
Compare the construction and the listed core sizes. Open a product for its dimensions and specification.
27 products
Unscreened
Cable construction
Unscreened
Share the materials, dimensions and operating conditions required by your equipment.
Discuss a custom cable →Inside the factory
See the silicone processing area and inspection work at ANYANG. Discuss the construction and operating requirements for your selected cable.

Inside silicone processing
Our production equipment includes silicone extruders and silicone rubber mixing machines.
Our process, quality inspection and custom development teams can review your specification and project requirements.
Why ANYANG
Factory facilities, drawing review and visible inspection work support a clear cable specification.
Silicone extrusion and rubber mixing equipment are part of our production facilities. Take a closer look at the workshop.
Inside the factoryConductor and format, Dimensions and terminations, Motion and verification: discuss these requirements with our process and custom development teams.
Custom cable supportView conductor-resistance testing and wire first-inspection work from our factory. Confirm the inspection and documentation requirements for the cable you select.
Quality & testing

Conductor design
The factory extra-flexible single-core sheet explicitly lists 0.08 mm strands. Confirm the selected size and strand count rather than applying one build to every product.

As one documented single-core example, the factory sheet lists 18 AWG with a 150/0.08 strand construction.
The same 18 AWG single-core example has silicone insulation and a listed 2.3 mm finished outside diameter. Conductor size is not the outside diameter.
For a sheathed cable, confirm core count, area per conductor, insulation, wrapping and total outside diameter using its own specification. Do not transfer the single-core strand details to another series.
Wire or cable
Compare the complete build as well as the conductor flexibility.
| Format | Documented construction | Installation review |
|---|---|---|
| Extra-flexible single-core | Tinned-copper stranding and silicone insulation; selected AWG sizes have their own strand and diameter entries. | Confirm the selected wire, route, terminal fit and movement requirement. |
| Extra-flexible sheathed | The factory reference lists Class 6 tinned copper, silicone core insulation, tissue-paper wrapping and silicone sheath. | The reviewed application note describes fixed installation and occasional movement; repeated-motion duty needs separate confirmation. |
Motion & sourcing
Choose a concrete strand or motion target, then verify the complete cable. The following custom options do not establish a category-wide flex-life rating.
For a finer-strand custom brief, discuss 0.05 mm or 0.07 mm individual-wire options. Set the strand count for the required cross-section and confirm finished diameter and terminal compatibility.
A high-temperature moving-cable candidate can combine Class 6 conductors, FEP core insulation, layered non-woven wrapping and a silicone sheath. A 10 × finished-diameter bend radius can be an initial qualification target, subject to the selected construction.
Agree radius, travel, speed, acceleration, temperature, load, cycle counting and target cycles. Check continuity, shorts, sheath damage and kinking; publish results for the tested construction and conditions.
Custom & supply
We manufacture custom cables to the agreed project specification. Share your drawing, operating conditions, quantity and delivery destination so we can define the construction, samples and supply terms.
Discuss your specificationPacking & delivery
Include the required length per coil or reel, order quantity, labelling and delivery destination. Packing method, minimum order quantity and lead time are confirmed for the project.
See packing & delivery information
Free samples
We offer free samples.
Confirm nominal size, strand count and strand diameter for the selected wire. One documented extra-flexible single-core example is 18 AWG with 150/0.08 construction and a 2.3 mm finished outside diameter.
The extra-flexible sheathed sheet lists 6 × cable diameter under fixed installation. It does not establish a continuous-motion bend radius. Have the moving installation reviewed separately.
Set the equipment duty and required cycle count, then agree a test with the radius, travel, speed, acceleration, temperature and tensile load recorded. The tested construction and acceptance checks accompany any released life result.
CABLE SELECTION & QUOTATIONS
You do not need an ANYANG model number. Share a drawing, existing cable marking or a description of your equipment.
Include the quantity you need and any known dimensions, voltage, temperature or movement requirements. We will check the specification with you.
claire@aycables.com