Unscreened
4-Core Silicone Cable – Extra-Flexible Tinned Copper
- Core sizes
- 0.5 mm² / 0.75 mm² / 1 mm² / 1.5 mm² / 2.5 mm² / 4 mm²
Silicone wire & cable / High-Temperature Silicone Wires & Cables
Silicone cable designs around 180°C (356°F) continuous-temperature requirements.
Choose a single-core lead for internal wiring or a silicone-sheathed multicore connection. Define the continuous temperature first, then select a separate short-time peak target, exposure duration and installation condition.

Reference construction illustration. Confirm the materials, layers and dimensions in the selected product drawing.
Browse the range
Compare the construction and the listed core sizes. Open a product for its dimensions and specification.
44 products
Unscreened
Unscreened
Unscreened
Share the materials, dimensions and operating conditions required by your equipment.
Discuss a custom cable →Inside the factory
See the silicone processing area and inspection work at ANYANG. Discuss the construction and operating requirements for your selected cable.

Inside silicone processing
Our production equipment includes silicone extruders and silicone rubber mixing machines.
Our process, quality inspection and custom development teams can review your specification and project requirements.
Why ANYANG
Factory facilities, drawing review and visible inspection work support a clear cable specification.
Silicone extrusion and rubber mixing equipment are part of our production facilities. Take a closer look at the workshop.
Inside the factoryTemperature and duration, Route and construction, Electrical duty and verification: discuss these requirements with our process and custom development teams.
Custom cable supportView conductor-resistance testing and wire first-inspection work from our factory. Confirm the inspection and documentation requirements for the cable you select.
Quality & testing

Temperature conditions
These are project design starting points. The released specification defines the limits for the selected construction, installation and qualification conditions.
| Thermal duty | Concrete design brief | Conditions to establish |
|---|---|---|
| Continuous heat | A 180°C (356°F) continuous-temperature requirement is a practical starting point for silicone equipment wiring. | Select the full conductor/insulation/sheath build and define the temperature at the cable, ventilation and movement. |
| Short-time heat excursion | For a 200°C (392°F), 220°C (428°F) or 250°C (482°F) peak requirement, develop a separately qualified material and cable specification. | Record exposure duration, number of cycles and acceptance after ageing; a peak target is not a continuous rating. |
| Cold installation and movement | State the lowest temperature and distinguish fixed routing from movement at that temperature. | Define the installation radius and inspect the selected construction under its agreed thermal and mechanical conditions. |
Heat & installation
Equipment temperature alone does not define the cable’s operating conditions.
Identify ducts, enclosures and restricted airflow. The reviewed factory AGR and YGG application notes call for adequate ventilation above 100°C (212°F).
Show the cable route and nearby hot surfaces. Include normal and peak exposure time in the application brief.
State whether the cable is fixed or moving, supported or under load. Review these conditions together with the temperature requirement.
Material & documents
The material and layer arrangement must be confirmed for the selected product.
Use the factory AGR direction: Class 5 tinned copper with silicone insulation. Define conductor size, voltage, colour, insulation wall and finished diameter for the connection.
Use the YGG layer arrangement for a multicore connection, selecting the core insulation separately. Add the YGGP overall copper braid when the equipment requires a screened version.
State the required documentation and test conditions. A silicone material description alone does not establish a fire rating or a verified service life.
Custom & supply
We manufacture custom cables to the agreed project specification. Share your drawing, operating conditions, quantity and delivery destination so we can define the construction, samples and supply terms.
Discuss your specificationPacking & delivery
Include the required length per coil or reel, order quantity, labelling and delivery destination. Packing method, minimum order quantity and lead time are confirmed for the project.
See packing & delivery information
Free samples
We offer free samples.
Write the normal cable temperature and a separate peak requirement. A 180°C (356°F) continuous brief can be combined with a project-specific 200°C (392°F), 220°C (428°F) or 250°C (482°F) short-time target, but the peak duration, cycles and qualified construction must be defined in the released specification.
Yes. The reviewed factory AGR and YGG application notes call for adequate ventilation above 100°C (212°F). Include enclosed or poorly ventilated routing in the application details.
Check both separately. The YGG factory sheet lists silicone or “Teflon” core insulation with a silicone outer sheath. Confirm the selected version.
Temperature and fire-performance requirements must be specified separately. Request evidence for the selected cable and the exact fire test required by the equipment.
CABLE SELECTION & QUOTATIONS
You do not need an ANYANG model number. Share a drawing, existing cable marking or a description of your equipment.
Include the quantity you need and any known dimensions, voltage, temperature or movement requirements. We will check the specification with you.
claire@aycables.com