Silicone cable designs around 180°C (356°F) continuous-temperature requirements.

Choose a single-core lead for internal wiring or a silicone-sheathed multicore connection. Define the continuous temperature first, then select a separate short-time peak target, exposure duration and installation condition.

High-Temperature Silicone Wires & Cables reference construction illustration
Selection priorities
  • Continuous & peak heat
  • Ventilation & routing
  • Complete cable build

Reference construction illustration. Confirm the materials, layers and dimensions in the selected product drawing.

Browse the range

Browse High-Temperature Silicone Wires & Cables

Compare the construction and the listed core sizes. Open a product for its dimensions and specification.

44 products

Need another construction?

Share the materials, dimensions and operating conditions required by your equipment.

Discuss a custom cable →

Inside the factory

Silicone Extrusion and Cable Manufacturing Support

See the silicone processing area and inspection work at ANYANG. Discuss the construction and operating requirements for your selected cable.

ANYANG workshop with a sign identifying the silicone extrusion area
Silicone extrusion area at ANYANG.

Inside silicone processing

Silicone extrusion and rubber mixing equipment

Our production equipment includes silicone extruders and silicone rubber mixing machines.

Our process, quality inspection and custom development teams can review your specification and project requirements.

Why ANYANG

Why Choose ANYANG for Custom Cable Supply?

Factory facilities, drawing review and visible inspection work support a clear cable specification.

Silicone processing facilities

Silicone extrusion and rubber mixing equipment are part of our production facilities. Take a closer look at the workshop.

Inside the factory

Temperature and Installation Review

Temperature and duration, Route and construction, Electrical duty and verification: discuss these requirements with our process and custom development teams.

Custom cable support

Conductor Testing and Wire Inspection

View conductor-resistance testing and wire first-inspection work from our factory. Confirm the inspection and documentation requirements for the cable you select.

Quality & testing
Conductor held in a resistance measurement fixture at ANYANG
Conductor-resistance testing at ANYANG.
ANYANG operator checking wire with measuring tools and an inspection sheet
Wire first-inspection work at ANYANG.

Temperature conditions

Silicone Cable Temperature Ratings and Heat Exposure

These are project design starting points. The released specification defines the limits for the selected construction, installation and qualification conditions.

Silicone Cable Temperature Ratings and Heat Exposure
Thermal dutyConcrete design briefConditions to establish
Continuous heatA 180°C (356°F) continuous-temperature requirement is a practical starting point for silicone equipment wiring.Select the full conductor/insulation/sheath build and define the temperature at the cable, ventilation and movement.
Short-time heat excursionFor a 200°C (392°F), 220°C (428°F) or 250°C (482°F) peak requirement, develop a separately qualified material and cable specification.Record exposure duration, number of cycles and acceptance after ageing; a peak target is not a continuous rating.
Cold installation and movementState the lowest temperature and distinguish fixed routing from movement at that temperature.Define the installation radius and inspect the selected construction under its agreed thermal and mechanical conditions.

Heat & installation

Ventilation, Hot Surfaces and Cable Movement

Equipment temperature alone does not define the cable’s operating conditions.

Enclosures and High-Temperature Ventilation

Identify ducts, enclosures and restricted airflow. The reviewed factory AGR and YGG application notes call for adequate ventilation above 100°C (212°F).

Hot Surfaces and Peak Exposure

Show the cable route and nearby hot surfaces. Include normal and peak exposure time in the application brief.

Fixed Routing, Movement and Tensile Load

State whether the cable is fixed or moving, supported or under load. Review these conditions together with the temperature requirement.

Material & documents

Single-Core and Multicore Designs for Hot Equipment

The material and layer arrangement must be confirmed for the selected product.

Single-Core Silicone Leads for Internal Wiring

Use the factory AGR direction: Class 5 tinned copper with silicone insulation. Define conductor size, voltage, colour, insulation wall and finished diameter for the connection.

Silicone-Sheathed Multicore Equipment Connections

Use the YGG layer arrangement for a multicore connection, selecting the core insulation separately. Add the YGGP overall copper braid when the equipment requires a screened version.

Product Specifications and Fire-Test Requirements

State the required documentation and test conditions. A silicone material description alone does not establish a fire rating or a verified service life.

Custom & supply

Custom cable production and supply for your project

We manufacture custom cables to the agreed project specification. Share your drawing, operating conditions, quantity and delivery destination so we can define the construction, samples and supply terms.

Discuss your specification
Temperature and duration
State continuous temperature, peaks, exposure duration and the lowest operating temperature.
Route and construction
Include ventilation, nearby hot surfaces, core insulation, sheath and dimensional limits.
Electrical duty and verification
Specify voltage, movement, required documents, acceptance tests and order quantity.

Packing & delivery

Supply lengths, labels and delivery requirements

Include the required length per coil or reel, order quantity, labelling and delivery destination. Packing method, minimum order quantity and lead time are confirmed for the project.

See packing & delivery information
Wrapped and labelled wire reels at ANYANG
Wrapped wire reels at ANYANG.

Free samples

Free Samples of High-Temperature Silicone Wires & Cables

We offer free samples.

Request free samples

High-Temperature Silicone Wires & Cables: questions before ordering.

How should I specify 180°C (356°F) continuous and a higher peak?

Write the normal cable temperature and a separate peak requirement. A 180°C (356°F) continuous brief can be combined with a project-specific 200°C (392°F), 220°C (428°F) or 250°C (482°F) short-time target, but the peak duration, cycles and qualified construction must be defined in the released specification.

Does ventilation matter?

Yes. The reviewed factory AGR and YGG application notes call for adequate ventilation above 100°C (212°F). Include enclosed or poorly ventilated routing in the application details.

Does a silicone sheath mean the core insulation is silicone?

Check both separately. The YGG factory sheet lists silicone or “Teflon” core insulation with a silicone outer sheath. Confirm the selected version.

Does a temperature rating establish fire resistance?

Temperature and fire-performance requirements must be specified separately. Request evidence for the selected cable and the exact fire test required by the equipment.

CABLE SELECTION & QUOTATIONS

Send your drawing or cable requirements.

You do not need an ANYANG model number. Share a drawing, existing cable marking or a description of your equipment.

Include the quantity you need and any known dimensions, voltage, temperature or movement requirements. We will check the specification with you.